INT161574

From wiki-pain
Jump to: navigation, search
Context Info
Confidence 0.73
First Reported 2004
Last Reported 2009
Negated 1
Speculated 0
Reported most in Body
Documents 7
Total Number 9
Disease Relevance 6.11
Pain Relevance 1.54

This is a graph with borders and nodes. Maybe there is an Imagemap used so the nodes may be linking to some Pages.

cytosol (CENPJ) cytoskeleton (CENPJ) cell division (CENPJ)
cytoplasm (CENPJ)
Anatomy Link Frequency
plasma 1
nasal 1
cardiogenic 1
lung 1
upper 1
CENPJ (Homo sapiens)
Pain Link Frequency Relevance Heat
depression 18 99.00 Very High Very High Very High
Analgesic 15 98.12 Very High Very High Very High
Opioid 54 93.56 High High
transcutaneous nerve stimulation 3 91.40 High High
cINOD 6 88.36 High High
anesthesia 49 87.80 High High
analgesia 9 73.44 Quite High
ischemia 2 64.72 Quite High
headache 12 54.12 Quite High
cva 3 45.00 Quite Low
Disease Link Frequency Relevance Heat
Sleep Apnea Syndromes 6 100.00 Very High Very High Very High
Airway Obstruction 47 99.92 Very High Very High Very High
Apnoea 354 99.84 Very High Very High Very High
Multiple System Atrophy 6 99.84 Very High Very High Very High
Pulmonary Disease 8 99.02 Very High Very High Very High
Respiratory Failure 19 99.00 Very High Very High Very High
Heart Rate Under Development 17 97.72 Very High Very High Very High
Sudden Death 4 95.60 Very High Very High Very High
Obstructive Sleep Apnea 163 94.72 High High
Pathologic Constriction 1 94.32 High High

Sentences Mentioned In

Key: Protein Mutation Event Anatomy Negation Speculation Pain term Disease term
The duration of nCPAP use at final visit was reduced from baseline by a mean (SD) of ?
Localization (use) of CPAP
1) Confidence 0.73 Published 2007 Journal Sleep Breath Section Body Doc Link PMC2194800 Disease Relevance 0.53 Pain Relevance 0.05
Patients’ use of nCPAP was monitored at least 2 weeks before baseline and throughout both studies using the Respironics REMstar Auto CPAP system.
Localization (use) of CPAP
2) Confidence 0.73 Published 2007 Journal Sleep Breath Section Body Doc Link PMC2194800 Disease Relevance 0.66 Pain Relevance 0
We must be cautious not to exacerbate upper airway obstruction by continuous positive airway pressure (CPAP), which is now increasingly used to treat sleep disordered breathing of MSA.
Localization (breathing) of CPAP in upper associated with airway obstruction, multiple system atrophy and sleep apnea syndromes
3) Confidence 0.42 Published 2009 Journal Rinsho Shinkeigaku Section Abstract Doc Link 19594101 Disease Relevance 1.50 Pain Relevance 0.09
CPAP leads to reductions in plasma norepinephrine levels by both increases in norepinephrine clearance and decreases in diurnal and nocturnal excretion compared with sham CPAP or oxygen supplementation alone (Mills et al 2006).
Localization (excretion) of CPAP in plasma
4) Confidence 0.39 Published 2006 Journal Neuropsychiatric Disease and Treatment Section Body Doc Link PMC2671821 Disease Relevance 0.47 Pain Relevance 0
Thus, at any given level of positive expiratory pressure with CPAP, EPAP, or PEEP, it is likely that regional lung unit volume can increase, decrease, or remain unchanged depending on regional mechanical properties and regional auto-PEEP levels.
Localization (pressure) of CPAP in lung
5) Confidence 0.15 Published 2004 Journal Crit Care Section Body Doc Link PMC420031 Disease Relevance 0 Pain Relevance 0
It is necessary that anaesthesiologists familiarize themselves with the use of CPAP devices, as determination of optimal CPAP setting may be difficult in patients who have not previously used CPAP.
Localization (setting) of CPAP
6) Confidence 0.10 Published 2008 Journal Indian Journal of Critical Care Medicine : Peer-reviewed, Official Publication of Indian Society of Critical Care Medicine Section Body Doc Link PMC2738308 Disease Relevance 0.49 Pain Relevance 0.13
It is necessary that anaesthesiologists familiarize themselves with the use of CPAP devices, as determination of optimal CPAP setting may be difficult in patients who have not previously used CPAP.
Neg (not) Localization (used) of CPAP
7) Confidence 0.10 Published 2008 Journal Indian Journal of Critical Care Medicine : Peer-reviewed, Official Publication of Indian Society of Critical Care Medicine Section Body Doc Link PMC2738308 Disease Relevance 0.48 Pain Relevance 0.12
Use of nasal CPAP in OSA patients may allow the use of systemic analgesic agents and reduce-haemodynamic changes, however, additional randomized clinical trials are required to further define the role of CPAP in this setting.


Localization (Use) of CPAP in nasal associated with apnoea and analgesic
8) Confidence 0.10 Published 2008 Journal Indian Journal of Critical Care Medicine : Peer-reviewed, Official Publication of Indian Society of Critical Care Medicine Section Body Doc Link PMC2738308 Disease Relevance 0.79 Pain Relevance 1.11
Besides patients with CHF and cardiogenic pulmonary edema, those patients with chronic obstructive pulmonary disease (COPD) may represent a second group of patients where application of CPAP and PEEP actually can be beneficial.
Localization (application) of CPAP in cardiogenic associated with heart rate under development and pulmonary disease
9) Confidence 0.04 Published 2005 Journal Crit Care Section Body Doc Link PMC1414045 Disease Relevance 1.19 Pain Relevance 0.03

General Comments

This test has worked.

Personal tools
Namespaces

Variants
Actions
Navigation
Toolbox